Service 06 · Space and architecture advice

HTM 03-01 and post occupancy evaluation: when the room itself is the cause.

Some problems cannot be solved with a different setting: a patient room next to the busy nurses’ station, a south-facing room without sun shading, a day room with harsh acoustics. Then we bring in our architectural knowledge. Based on the readings, we show what is needed in the building and coordinate it with your planners and contractors.

How it runs

Step by step, from the first conversation.

Who it is for

  • Facilities before refurbishment
  • Buildings with recurring problems that operations cannot solve
  • Planners who need readings from existing buildings
  1. 1

    Narrow down the cause

    From the readings we see where the room itself is the cause.

  2. 2

    Work out recommendations

    Acoustics, light, sun shading, materials or room layout – ordered by impact and effort.

  3. 3

    Coordinate

    We discuss the recommendations with you and your planners.

  4. 4

    Check the effect

    After implementation, the sensors show whether things have improved.

What you get

  • Architectural recommendations based on real readings
  • Coordination with your planners
  • Before-and-after comparison

What we need from you

  • Floor plans and drawings
  • A contact person for construction and planning

FAQ

Frequently asked questions

Healthcare building retrofit: what are the typical mistakes?

Common patterns are carrying problems forward (a south-facing room without external shading is refurbished and still overheats), sizing rooms from assumptions rather than actual use, underestimating noise near nurses' stations or lifts, involving infection prevention too late, and having no baseline. Measuring before a healthcare building retrofit avoids most of these. Fact & Feeling provides that baseline room by room and does not replace architects or engineers.

Care home refurbishment: what should be measured first?

Before an energy retrofit, measure how warm residents' rooms get in summer and how well they are aired. Rooms on top floors and on south- and west-facing sides usually warm up faster. These readings help the design team decide on shading and ventilation, and the same sensors show after the care home refurbishment whether conditions improved. Funding for care homes follows different routes from hospital funding; owners clarify options with their advisers.

How can decarbonising healthcare buildings avoid worse room conditions?

Decarbonising healthcare buildings often means changing heating systems, envelopes and ventilation. Room data from before the work gives a reference: if comfort or air quality changes after a retrofit, the team can see it and act, which matters in buildings that run around the clock. No savings follow automatically from measurement; energy assessment stays with energy consultants and engineers.

Hospital space utilization: how can room use be measured without counting people?

Fact & Feeling does not count or identify people. Room use comes from the facility's own booking and room-use schedules; the CO₂ trend can add an indirect indication of whether a room was in use at a given time, without saying who or how many people were there. This adds a time dimension to hospital space utilization data, for example which treatment rooms are used for two hours a day and which are full from morning to evening.

Space utilisation study NHS: what do the estate figures show?

In England, space utilisation is tracked through trusts' annual Estates Returns Information Collection (ERIC). Following the Carter review, targets were a maximum of 35% non-clinical floor space and less than 2.5% under-utilised space; by 2022/23, under-utilised space had fallen to 1.9% of occupied floor area. These figures describe the estate as a whole; a space utilisation study NHS trusts run at ward level needs room-by-room data over time.

Evidence-based design: healthcare research or data from your own building?

Both. In evidence-based design, healthcare building decisions are grounded in research; a widely cited 2008 review by Ulrich and colleagues discusses features such as single-bed rooms and a good acoustic environment. The review describes associations, not a guarantee for any particular building. Measured data from your own rooms adds what general studies cannot know about your site, orientations and neighbouring uses.

Healing environment hospital design: what does it mean in practice?

A healing environment is a design approach in which light, sound, temperature and room layout are shaped around the people using the space. It describes an intention, not an effect that can be promised for a single room. Measured room data shows whether healing environment hospital design works in daily use: how bright, how loud and how warm rooms really are. Fact & Feeling measures these conditions and recommends architectural changes where the room itself is the cause.

Indoor environmental quality healthcare: which factors count?

A 2024 systematic review names daylight, thermal comfort, acoustics and indoor air quality as the components of indoor environmental quality. Healthcare studies in the review associate good IEQ with recovery, less stress and shorter stays, but how the factors interact is little studied. Fact & Feeling measures CO₂, particulate matter, VOC, temperature, humidity, light level and sound level room by room, so IEQ in healthcare buildings becomes visible over time.

Post-occupancy evaluation hospital: how do you compare before and after?

Post-occupancy evaluation (POE) assesses a building once it is in use. A review by Brambilla and Capolongo compared 13 POE tools for hospitals and found acoustics accounted for only about 2% of indicators. Measured room data from before the refurbishment gives a baseline, and data after occupation gives the comparison. With Fact & Feeling's monitoring, devices can stay after the work, so a post-occupancy evaluation, hospital-wide or per ward, can compare conditions with the baseline.

What is a TM59 overheating assessment, and how does room data complement it?

CIBSE TM59 is a design methodology for assessing overheating risk in homes, which can also be applied to care homes. It predicts risk at design stage for new and refurbished buildings under defined assumptions; it does not show which rooms of an existing building overheated last summer. Measured temperatures per room complement a TM59 overheating assessment and help set priorities, but do not replace it.

What are Health Building Notes, and where does measured data fit?

Health Building Notes are NHS England guidance on the design and planning of new healthcare buildings and on adapting or extending existing facilities (as of October 2026, not legal advice). They set the standard for what a room should provide. Measured data from comparable existing rooms adds what guidance cannot know: how a particular site, its orientations and neighbouring uses behave.

What does HBN 00-09 ask for in a building project?

Health Building Note 00-09 covers infection control in the built environment and asks for the infection prevention and control team to be consulted throughout every stage of a capital project (as of October 2026, not legal advice). Teams that involve IPC too late often end up redesigning. Room data on temperature and humidity can support the IPC team's discussions, but HBN 00-09 decisions stay with them.

What does HTM 03-01 mean for ventilation in a refurbishment?

HTM 03-01 is NHS England guidance on specialised ventilation for healthcare premises. It expects ventilation to be monitored via a building management system, critical systems to be inspected quarterly and verified at least annually, and recommends keeping humidity below 70% (as of October 2026, not legal advice). Room sensors do not replace HTM 03-01 testing or the IPC team, but show how rooms around these systems behave over time.